MANUFACTURED or HUD Homes
|
MODULAR or UBC or IRC Homes
|
| 1
|
2" x 6" #3 Floor Joists or better
|
2" x 10" #2 Floor Joists (truss TJI available)
|
| 2
|
2" x 6" Single Perimeter Rim Joist
|
2" x 10" Double Perimeter Rim Joist
|
| 3
|
R-11 Floor Insulation
|
R-11 Floor Insulation Perimeter Only
|
| 4
|
16" Overhang
|
16" Overhang
|
| 5
|
30# Roof Load (HUD Rafter)
|
30# Roof Load w/ 5/12 Roof Pitch (Heavier Rafter)
|
| 6
|
Load Bearing Walls (Sidewall & Marriage Wall)
Will have Single 2X Top Plate & 1 2X Bottom Plate
|
Load Bearing Walls (Sidewall & Marriage Wall)
Will Have Double 2X Top Plate & 1 2X Bottom Plate.
|
| 7
|
Double Flat 2" x 6" Window & Door Headers
|
Triple Vertical 2" x 6" Window & Door Headers w/Jack Studs
|
| 8
|
24" On Center Marriage Wall
|
16" On Center Marriage Wall
|
| 9
|
2" x 4" Interior Wall Studs 24" O.C.
|
2" x 4" Interior Wall Studs 16" O.C.
|
| 10
|
R-26 or R-30 Roof Insulation
|
R-38 Roof Insulation
|
| 11
|
Std. Plumbing Auto Vents
|
3" Roof Venting (No Auto Vents)
|
| 12
|
Std.Through the Roof Plumbing Vents
|
Through The Roof Plumbing Vents w/3" Diameter Vents
|
| 13
|
Std. 1½" P-Traps & Waste Pipe Sizes
|
2" P-Traps & Waste Pipes For Tubs & Showers
|
| 14
|
No Water Shut Offs Required
|
Water Shut Offs Required @ All Plumbing Fixtures
|
| 15
|
No Frost Free Exterior Faucet
|
Exterior Frost Free Faucet Required
|
| 16
|
Non Anti Scald Valves On Tubs & Showers
|
Anti Scald Valves On All Tubs & Showers
|
| 17
|
No Over Flows On Tubs
|
All Tubs Have Overflows
|
| 18
|
Main Water Shut Off Not Required
|
¾" Main Water Shut Off Required
|
| 19
|
Std. Washer Drain & Vent
|
IRC 2" Washer Drain & Vent
|
| 20
|
Smoke Detectors In All Bedrooms & Living Areas Are Protected from Kitchen
|
IRC Smoke Detector Inside Each Bedroom & Outside Each Bedroom Area
|
| 21
|
Up To 15 Electrical Receptacles Per Circuit
|
No More Than 10 Electrical Receptacles Per Circuit
|
| 22
|
Receptacles Near Sink Above Countertops Are GFI Protected
|
All Receptacles Above Countertop Are GFI Protected
|
| 23
|
Amp Connectors On All 12-2 and 14-2 Wires, Junction Boxes Used On All Others
|
Electrical Junction Boxes W/Plain Covers Will Be Installed At Front & Rear Of Home. If Fuse Box Is On The Kitchen Side, 4 Boxes Are Required. If Fuse Box Is On Opposite Side of Kitchen, 6 Boxes Are Required.
|
| 24
|
Standard Exterior GFI
|
Exterior Receptacles Will Have A Bubble Cover That Will Close With A Cord Plugged In.
|
| 25
|
Electrical Receptacles 12" From Edge Of Countertops And Spaced 72" Apart
|
Electrical Receptacles 12" From Edge Of Countertops & Spaced 24" Apart
|
| 26
|
All Romex Wire Secured w/Standard Staples
|
All Romex Wire Is Secured with Non-Metallic Staples
|
| 27
|
100 Amp Electrical Service
|
200 Amp Long Panel Electrical Box (BRK2040B200PKW)
|
| 28
|
Standard HUD Required Breakers
|
Use Full Slot (¾") 120-Volt Breakers & 2 slot (1½") 220-Volt Breakers. No double Slot Breakers Allowed.
|
| 29
|
Sealed Combustion Gas Water Heater w/Fresh Air Intake From Outside Home
|
Water Heater( per ubc)
|
| 30
|
No Attic Access Required
|
Attic Access Is Required and Must be 22" x 30" Minimum w/30" Unobstructed Head Room & An Attic Light w/Switch
|
|
Please note: These are just some of the main points between products, other items adjust according to local municipality. State, Local and 3rd Party